Sample Record for 2021-10-27-13
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215704 DEA: 020J9104 EFIS: 0219000174
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS,MOD,SHA-89,139,299-VAR
Work Description: REPAIR UNSOUND CONCRETE, POLYESTER CONCRETE OVERLAYS, JOINT SEALS.
Location Description: LASSEN, MODOC, AND SHASTA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 2990 Bay Vista Court, Benicia, CA 95122
Resident Engineer: Tofael Anwar Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2021-10-27-13
TL Number from the TL Form: 875743
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 10/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/27/2021
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: Lime Treated 3/4-inch Type A Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: D78967
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JF Shea Construction - Fawndale Rock and Asphalt - Redding, CA
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-45-0017
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Mathematically Combined
Where the material sample would have been placed if not sampled: 02 MOD LAS SIS SHA VAR
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:
Test Results
Test 1 of 1
DIME Test ID: 2021-10-27-13-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 11/18/2021
Date Tested: 11/03/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
87 %
|
Cumulative percent passing the 3/8 in. sieve
|
76 %
|
Cumulative percent passing the #4 sieve
|
53 %
|
Cumulative percent passing the #8 sieve
|
34 %
|
Cumulative percent passing the #16 sieve
|
22 %
|
Cumulative percent passing the #30 sieve
|
15 %
|
Cumulative percent passing the #50 sieve
|
11 %
|
Cumulative percent passing the #100 sieve
|
8 %
|
Cumulative percent passing the #200 sieve
|
6.0 %
|