Print Report | Back to Sample Detail

Sample Record for 2021-10-26-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215589 DEA: 112N0084 EFIS: 1117000153 QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-7,8,78,86,98,111-Var
Work Description: METHACRYLATE BRIDGE DECKS, REPAIR SPALLS AND REPLACE JOINT SEALS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS.
Contractor Name: FEC Future Contractors & Engineers, Inc
Contractor Address: 184 Technology Dr., Ste 2, Irvine, CA 92618
Resident Engineer: David Toci Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-10-26-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 594-1991
Type of Sample: Authorization
Type of Material: Methacrylate
Sample Taken Date: 10/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/26/2021
The quantity of what the sample constitutes: 1 quart can
A brief description of the sample: HMWM
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Transpo Industries Inc

Material Information

Mfg. Lot Number(s): 1004217010
Batch number: 1004217010
Mix number: 3568

Test Results

Test 1 of 1

DIME Test ID: 2021-10-26-10-1
Test Method: CONCLP 4-16: HMWM
Verified Date: 10/26/2021
Date Tested: 10/26/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F 24.8
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F 1.01
Volatile content (ASTM D 2369) 30% max 25
Flash point (ASTM D 3828) more than 180 deg F 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours no data psi
Tack free time, 400 minutes max 395