Print Report | Back to Sample Detail

Sample Record for 2021-10-26-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215164 DEA: 07317304 EFIS: 0715000237 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60-0.0/R3.2,11.8/R21.5
Work Description: UPGRADE EXISTING OVERHEAD AND ROADSIDE SIGN PANELS.
Location Description: LOS ANGELS COUNTY FROM 0.4 MILE WEST OF ROUTE 5/60 SEPARATION TO ROUTE 60/710 SEPARATION AND FROM ROUTE 60/605 SEPARATION TO FAIRWAY DRIVE UNDERCROSSING
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 CONSTRUCTION CIRCLE WEST, IRVINE CA 92606
Resident Engineer: Myrna Dominguez Structure Rep.: Avtar Bains

Sample Information

DIME Sample ID: 2021-10-26-7
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Control
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 10/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 11/02/2021
The quantity of what the sample constitutes: (16) #14 ZAP Coupler
A brief description of the sample: (16) #14 ZAP Coupler
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Camblin Steel Service

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC
Coupler Manufacturer: Double Row ZAP Screwlok Type 2 Series
Intermediate Assembler or Fabricator: Camblin Steel
Rebar Size: #14
Coupler Model: Double Zap Screwlok Type 2
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): MM20106095
Rebar Heat Number(s): 9002146
Rebar Size 2 : 14
Coupler Unique ID:

Test Results