Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215522 DEA: 112N0994 EFIS: 1121000028
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R32.0/R44.0
Work Description: REPLACE INDIVIDUAL SLABS AND JOINT SEAL, COLD PLANE AND PAVE WITH HMA.
Location Description: SAN DIEGO COUNTY NEAR ALPINE FROM 0.2 MILE EAST OF VIEJAS CREEK BRIDGE TO 0.9 MILE WEST OF SUNRISE HIGHWAY OVERCROSSING
Contractor Name: RV Concrete
Contractor Address: 605 E Commercial Street, Anaheim, CA 92801
Resident Engineer: David Timms Structure Rep.: Unknown
DIME Sample ID: 2021-07-22-51
TL Number from the TL Form: C963251
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 07/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCA-Lake Elsinore
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2021-07-22-51-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 10/27/2021
Date Tested: 10/26/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
62 C
|
Softening Point Sample 2
|
62 C
|
Bath Liquid
|
freshly boiled distilled water
|
Minutes Reaction
|
no data
|
DIME Test ID: 2021-07-22-51-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/27/2021
Date Tested: 10/27/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination
|
Unworked Penetration
|
Unworked Penetration
|
42 0.1 mm
|
DIME Test ID: 2021-07-22-51-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/27/2021
Date Tested: 10/27/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
66 mm
|
Ball Penetration (P1)
|
2 mm
|
Final Dial reading (F2)
|
66 mm
|
Ball Penetration (P2)
|
1 mm
|
Final Dial reading (F3)
|
67 mm
|
Ball Penetration (P3)
|
2 mm
|
Resilience 1
|
36 %
|
Resilience 2
|
35 %
|
Resilience 3
|
35 %
|
Average Resilience
|
35 %
|
Minutes Reaction
|
no data
|