Work Description: TROUT CREEK BRIDGE REPLACEMENT
Location Description: IN SAN LUIS OBISPO COUNTY ON HWY 58 EAST OF SANTA MARGARITA AT TROUT CREEK BRIDGE (BR NO. 49-0091).
Contractor Name: SOUZA CONSTRUCTION
Contractor Address: 4027 Santa Fe Road, San Luis Obispo, CA 93403
Resident Engineer: Thomas Petersen Structure Rep.: Salvador Heredia
DIME Sample ID: 2021-10-20-21
TL Number from the TL Form: C918914
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/20/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/20/2021
The quantity of what the sample constitutes: 1
A brief description of the sample: A449 ATR with Coupling Nut
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BSMI
Rocap Number(s):
Heat Number(s): 10648850
Nut Mfg. Lot Number(s): S01210302H
Washer Mfg. Lot Number(s):
Bolt Specification: None
Bolt Length(s):
Nut Specification: A563 Coupling Nut
Washer Specification: None
Finish: F2329
Diameter/Size:
Bolt Mfg. Lot Number: 2103153-20
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2021-10-20-21-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 10/26/2021
Date Tested: 10/22/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Broke in Half
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1 | UNC 7/8 | 0.462 | 62983 | 280 | 136247 | 122845 | 56755 | Nut Broke in Half |
| |
UTM
|
400kip
|
Temperature
|
72
|