Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215095 DEA: 11419304 EFIS: 1115000042
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.6/R21.3
Work Description: PLACE HMA AND RHMA, CURB RAMPS, AND ELECTRICAL WORK.
Location Description: SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.1 MILE WEST OF NORTH BROADWAY TO FLORA VISTA STREET
Contractor Name: HAZARD CONSTRUCTION COMPANY
Contractor Address: 10529 Vine Streeet, Lakeside, CA 92040
Resident Engineer: Gary LeVine Structure Rep.: Unknown
DIME Sample ID: 2021-09-22-69
TL Number from the TL Form: C963261
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCA-Lake Elsinore
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2021-09-22-69-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 10/25/2021
Date Tested: 10/22/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
64 C
|
Softening Point Sample 2
|
65 C
|
Bath Liquid
|
freshly boiled distilled water
|
Minutes Reaction
|
no data
|
DIME Test ID: 2021-09-22-69-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/25/2021
Date Tested: 10/23/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination
|
Unworked Penetration
|
Unworked Penetration
|
21 0.1 mm
|
DIME Test ID: 2021-09-22-69-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/25/2021
Date Tested: 10/23/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
59 mm
|
Ball Penetration (P1)
|
0 mm
|
Final Dial reading (F2)
|
58 mm
|
Ball Penetration (P2)
|
0 mm
|
Final Dial reading (F3)
|
59 mm
|
Ball Penetration (P3)
|
0 mm
|
Resilience 1
|
41 %
|
Resilience 2
|
42 %
|
Resilience 3
|
41 %
|
Average Resilience
|
41 %
|
Minutes Reaction
|
no data
|