Sample Record for 2021-07-30-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215063 DEA: 032F5704 EFIS: 0300020615 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-46.3/63.5
Work Description: Replace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay)
Location Description:
Contractor Name: Walsh Construction Company II, LLC (Walsh)
Contractor Address: 1390 Willow Pass Road Suite 950, Concord, CA 94520
Resident Engineer: Tad Sampson Structure Rep.: Jimmer Ross

Sample Information

DIME Sample ID: 2021-07-30-37
TL Number from the TL Form:
Sample Submitted By Organization: Kie-Con, Incorporated - Antioch
Sample Organization Contact: (925) 331-7122
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/30/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2021
The quantity of what the sample constitutes: 25 CY
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KIE-CON, INC

Material Information

The concrete mix design number: K5670-100 CPA R3
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 111404
Concrete batch plant:
The fabricator/manufacturer designation for the sample: 20-111C 7/30/2021
A detailed description of where the material sample was collected: Concrete sample from wheelbarrow
Where the material sample would have been placed if not sampled: Voided Slab
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2021-07-30-37-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/20/2021
Date Tested: 07/30/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: gregory.lask@kiewit.com
Organization Phone: (925) 331-7122
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 76 F

Test 2 of 6

DIME Test ID: 2021-07-30-37-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/20/2021
Date Tested: 07/30/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: gregory.lask@kiewit.com
Organization Phone: (925) 331-7122
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 7.25 inch

Test 3 of 6

DIME Test ID: 2021-07-30-37-3
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 10/20/2021
Date Tested: 07/30/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: gregory.lask@kiewit.com
Organization Phone: (925) 331-7122
General Comments for this Test: Sample took place after both truck sat for a few minutes while previous load finished discharge, and then discharge of half of the load. Caltrans QA was okay with air result provided subsequent testing was within range. Immediate testing of next truck was not possible owing to finishing sample testing and cleanup. Loads 7 and 8 were tested, 7 was rejected for air and slump, 8 was acceptable.
Test Result Compliance:
Additional Comments When Verified:
Air content 4.3 %

Test 4 of 6

DIME Test ID: 2021-07-30-37-4
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 10/20/2021
Date Tested: 07/30/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: gregory.lask@kiewit.com
Organization Phone: (925) 331-7122
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample 111404
Volume of the measure 0.25 ft^3
Density of concrete 147.2 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data

Test 5 of 6

DIME Test ID: 2021-07-30-37-5
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/20/2021
Date Tested: 08/02/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: gregory.lask@kiewit.com
Organization Phone: (925) 331-7122
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 6620 psi
Maximum load on cylinder 1 190550 lb
Maximum load on cylinder 2 183910 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 2 days
Age of specimen in hours 0 hours

Test 6 of 6

DIME Test ID: 2021-07-30-37-6
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/20/2021
Date Tested: 08/28/2021
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: gregory.lask@kiewit.com
Organization Phone: (925) 331-7122
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 8990 psi
Maximum load on cylinder 1 262370 lb
Maximum load on cylinder 2 246050 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 29 days
Age of specimen in hours 0 hours