Print Report | Back to Sample Detail

Sample Record for 2021-10-08-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214685 DEA: 024E46U4 EFIS: 0216000122 QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-36-6.0/14.6
Work Description: REPLACE BRIDGE, ROADWAY EXCAVATION, HMA, CLASS 2 AB AND DRAINAGE WORK.
Location Description: LASSEN COUNTY NEAR WESTWOOD FROM 1.3 MILES WEST OF GOODRICH CREEK BRIDGE TO 1.0 MILE WEST OF WILLARD CREEK ROAD
Contractor Name: Hat Creek Construction
Contractor Address: 24339 Highway 89 N, Burney, CA 96013
Resident Engineer: Tim Crosby Structure Rep.: Jeff Rothgery

Sample Information

DIME Sample ID: 2021-10-08-17
TL Number from the TL Form: 695653
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Department Acceptance
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 10/08/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/09/2021
The quantity of what the sample constitutes: 1 bag RAP for PSE
A brief description of the sample: 3/8 Inch RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D78954
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction, Ward Lake Plant, Litchfield, CA

Material Information

RAP Source: Hat Creek Construction and Materials, Ward Lake Facility, Litchfield, CA
Aggregate Size: 3/8 Inch
Aggregate Source: Unknown
RAP Stockpile: Continuous
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2021-10-08-17-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/21/2021
Date Tested: 10/11/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 99.4 %
Cumulative percent passing the 1/4 in. sieve 81.9 %
Cumulative percent passing the #4 sieve 69.6 %
Cumulative percent passing the #8 sieve 47.7 %
Cumulative percent passing the #16 sieve 34.7 %
Cumulative percent passing the #30 sieve 26.5 %
Cumulative percent passing the #50 sieve 19.8 %
Cumulative percent passing the #100 sieve 14.2 %
Cumulative percent passing the #200 sieve 10.3 %

Test 2 of 3

DIME Test ID: 2021-10-08-17-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/21/2021
Date Tested: 10/11/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Uncorrected binder content of RAP
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 6.41 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 3 of 3

DIME Test ID: 2021-10-08-17-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/21/2021
Date Tested: 10/11/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7336.5 grams
Mass of oven-dry sample in air for Sample 1 1604 grams
Mass of container filled with the sample and water for Sample 1 8294.7 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.484
Theoretical maximum density at 25°C (77°F) no data