Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215417 DEA: 101K9304 EFIS: 1020000014
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-VAR,580-VAR
Work Description: BRIDGE DECKS INVESTIGATION AND REHABILITATION IN AND NEAR TRACY
Location Description: SJ CTY IN & NEAR TRACY FROM GAFFERY RD TO EAST MIDWAY
Contractor Name: Meyers & Sons
Contractor Address: Unknown
Resident Engineer: Bal Bahadur Paul Structure Rep.: Ron Matin
DIME Sample ID: 2021-10-15-5
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 10/15/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/15/2021
The quantity of what the sample constitutes: 2 Tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt
DIME Test ID: 2021-10-15-5-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2021-10-15-5-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2021-10-15-5-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.49 in
|
Sample 1 Ultimate strength
|
2583.2 psi
|
Sample 1 Thickness
|
0.238 in
|
Sample 1 Area
|
0.1166 in^2
|
Sample 1 Ultimate Strength Actual
|
301.2 lbs
|
Sample 1 percent elongation
|
39.3 %
|
Sample 1 Time
|
3 MM:SS
|
Sample 2 Width
|
0.492 in
|
Sample 2 Thickness
|
0.245 in
|
Sample 2 Area
|
0.1205 in^2
|
Sample 2 Ultimate strength
|
2735.3 psi
|
Sample 2 Ultimate Strength Actual
|
329.6 lbs
|
Sample 2 percent elongation
|
41.1 %
|
Sample 2 Time
|
2 MM:SS
|
Sample 3 Width
|
0.49 in
|
Sample 3 Thickness
|
0.253 in
|
Sample 3 Area
|
0.124 in^2
|
Sample 3 Ultimate strength
|
2810.5 psi
|
Sample 3 Ultimate Strength Actual
|
348.5 lbs
|
Sample 3 percent elongation
|
55.2 %
|
Sample 3 Time
|
3 MM:SS
|
Sample 4 Width
|
0.491 in
|
Sample 4 Thickness
|
0.251 in
|
Sample 4 Area
|
0.1232 in^2
|
Sample 4 Ultimate strength
|
2614.4 psi
|
Sample 4 Ultimate Strength Actual
|
322.1 lbs
|
Sample 4 percent elongation
|
37.3 %
|
Sample 4 Time
|
2 MM:SS
|
Sample 5 Width
|
0.49 in
|
Sample 5 Thickness
|
0.257 in
|
Sample 5 Area
|
0.1259 in^2
|
Sample 5 Ultimate strength
|
3032.6 psi
|
Sample 5 Ultimate Strength Actual
|
381.8 lbs
|
Sample 5 percent elongation
|
64.5 %
|
Sample 5 Time
|
4 MM:SS
|
Sample 6 Width
|
0.49 in
|
Sample 6 Thickness
|
0.258 in
|
Sample 6 Area
|
0.1264 in^2
|
Sample 6 Ultimate strength
|
2849.7 psi
|
Sample 6 Ultimate Strength Actual
|
360.2 lbs
|
Sample 6 percent elongation
|
53.4 %
|
Sample 6 Time
|
4 MM:SS
|
Ultimate Strength Average
|
2771 psi
|
Percent Elongation Average
|
48 %
|
DIME Test ID: 2021-10-15-5-4
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1849.16 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
PCC
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
924.58 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1810.19 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
PCC
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
905.095 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1436.03 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
PCC
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
718.015 psi
|
DIME Test ID: 2021-10-15-5-5
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
46
|
DIME Test ID: 2021-10-15-5-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/29/2021
Date Tested: 10/29/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
75 f
|
Tare weight
|
no data0 grams
|
Initial weight
|
100 grams
|
Weight at 5 minutes
|
99.926 grams
|
Weight at 10 minutes
|
99.874 grams
|
Weight at 15 minutes
|
99.818 grams
|
Weight at 20 minutes
|
99.737 grams
|
Weight at 25 minutes
|
99.669 grams
|
Weight at 30 minutes
|
99.6 grams
|
Final weight
|
99.6 grams
|
Total weight loss
|
0.4 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
21.503 grams/m^2
|