Print Report | Back to Sample Detail

Sample Record for 2021-10-14-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-10-14-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 10/14/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2021
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: 1 1/2 PCC Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex Bullhead City

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-36-0068::REDLANDS WASH PLAN (CEMEX)
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: at plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1-1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2021-10-14-3-1
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 10/14/2021
Date Tested: 10/13/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: DIME Long Term Planning - Test
Test Result Compliance:
Additional Comments When Verified: DIME Long Term Planning - Test
What type of gradation is being tested? Combined Gradation
Cumulative mass retained on the 2 in. sieve 0 grams
Cumulative mass retained on the 1 1/2 in. sieve 0 grams
Cumulative mass retained on the 1 in. sieve 0 grams
Cumulative mass retained on the 3/4 in. sieve 8 grams
Cumulative mass retained on the 1/2 in. sieve 39 grams
Cumulative mass retained on the 3/8 in. sieve 0 grams
Cumulative mass retained on the #4 sieve 6 grams
Cumulative mass retained on the #8 sieve 5 grams
Cumulative mass retained on the #16 sieve 13 grams
Cumulative mass retained on the #30 sieve 8 grams
Cumulative mass retained on the #50 sieve 12 grams
Cumulative mass retained on the #100 sieve 7 grams
Cumulative mass retained on the #200 sieve 1 grams
Cumulative mass retained on the pan 1 grams
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 92 %
Cumulative percent passing the 1/2 in. sieve 53 %
Cumulative percent passing the 3/8 in. sieve 53 %
Cumulative percent passing the #4 sieve 47 %