Print Report | Back to Sample Detail

Sample Record for 2021-10-12-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-I-15,SR-91-6.1-7.6
Work Description: I-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location Description: Junction of I-15 and SR-91 in Corona, CA
Contractor Name: Myers-Rados Joint Venture
Contractor Address: 629 N. Main Street, Suite C3, Corona, CA 92878
Resident Engineer: Roy Fisher Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2021-10-12-12
TL Number from the TL Form: 3
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Annual Source Testing
Type of Material: Concrete
Sample Taken Date: 10/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/13/2021
The quantity of what the sample constitutes: 9
A brief description of the sample: concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1026-03
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1419984
The truck number from where the sample was collected: 10066592
The batch plant ticket number from where the sample was collected: 2901072
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: A Line Station 420 25
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2021-10-12-12-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/21/2021
Date Tested: 10/19/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Average diameter of cylinder 3 5.98 in
Average diameter of cylinder 4 5.97 in
Average diameter of cylinder 5 5.98 in
Average diameter of cylinder 6 5.98 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.18 in^2
Cross sectional area of cylinder 3 28.09 in^2
Cross sectional area of cylinder 4 27.99 in^2
Cross sectional area of cylinder 5 28.09 in^2
Cross sectional area of cylinder 6 28.09 in^2
Compressive strength (to nearest 10 psi) 770 psi
Maximum load on cylinder 1 21890 lb
Maximum load on cylinder 2 22040 lb
Maximum load on cylinder 3 21535 lb
Maximum load on cylinder 4 20965 lb
Maximum load on cylinder 5 21970 lb
Maximum load on cylinder 6 21010 lb
Compressive strength of cylinder 1 779.3 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 782.1 psi
Compressive strength of cylinder 3 766.6 psi
Compressive strength of cylinder 4 749 psi
Compressive strength of cylinder 5 782.1 psi
Compressive strength of cylinder 6 748 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Type of fracture pattern of cylinder 4 2
Type of fracture pattern of cylinder 5 2
Type of fracture pattern of cylinder 6 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Correction factor for cylinder 5 1
Correction factor for cylinder 6 1
Age of specimen 0 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Test 2 of 2

DIME Test ID: 2021-10-12-12-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/09/2021
Date Tested: 11/09/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 0 lb
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Average diameter of cylinder 3 5.98 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.18 in^2
Cross sectional area of cylinder 3 28.09 in^2
Compressive strength (to nearest 10 psi) 1470 psi
Maximum load on cylinder 1 41720 lb
Maximum load on cylinder 2 40910 lb
Maximum load on cylinder 3 41290 lb
Compressive strength of cylinder 1 1485.2 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 1451.7 psi
Compressive strength of cylinder 3 1469.9 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 0 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.