Print Report | Back to Sample Detail

Sample Record for 2021-10-13-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215753 DEA: 050N72U4 EFIS: 0520000169 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-4.4/R7.7
Work Description: Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description: 101 freeway in Summerland, CA
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Road, Santa Barbara, CA 93111
Resident Engineer: Taylor Merlo Structure Rep.: Emiliano Berntsen

Sample Information

DIME Sample ID: 2021-10-13-13
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California, LLC
Sample Organization Contact: 661-630-7162
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/13/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/13/2021
The quantity of what the sample constitutes: One box girder
A brief description of the sample: PCC
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier: 51-0364
Structure name: Arroyo Paredon Creek Bridge
The fabricator/manufacturer/facility name: Con-Fab California, LLC

Material Information

The concrete mix design number: SCC-S95-0F
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1826
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of truck discharge chute
Where the material sample would have been placed if not sampled: box girders
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 7

DIME Test ID: 2021-10-13-13-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/14/2021
Date Tested: 10/13/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 75 F

Test 2 of 7

DIME Test ID: 2021-10-13-13-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 10/14/2021
Date Tested: 10/13/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample SCC
Volume of the measure 0.25 ft^3
Density of concrete 152.5 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content 1.3 %

Test 3 of 7

DIME Test ID: 2021-10-13-13-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/14/2021
Date Tested: 10/14/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Apparent mass of submerged cylinder 1 29.9 lb
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5550 psi
Maximum load on cylinder 1 159280 lb
Maximum load on cylinder 2 154250 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 0 days
Age of specimen in hours 16 hours
Serial number of delivery ticket, if available 1826

Test 4 of 7

DIME Test ID: 2021-10-13-13-4
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 10/14/2021
Date Tested: 10/13/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Precast Maximum Curing Temperature 145 °F

Test 5 of 7

DIME Test ID: 2021-10-13-13-5
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 10/14/2021
Date Tested: 10/13/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air content 1.3 %

Test 6 of 7

DIME Test ID: 2021-10-13-13-6
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/14/2021
Date Tested: 10/13/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 25 inch

Test 7 of 7

DIME Test ID: 2021-10-13-13-7
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/20/2021
Date Tested: 10/20/2021
Submitted By Organization: Con-Fab California, LLC
Organization Address: 701 Golds Ave,
Organization City: Shafter
Organization State: CA
Organization Zipcode: 93263
Organization Email: trevorl@confabca.com
Organization Phone: 661-630-7162
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 29.9 lb
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Average diameter of cylinder 3 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Cross sectional area of cylinder 3 28.27 in^2
Compressive strength (to nearest 10 psi) 8900 psi
Maximum load on cylinder 1 254820 lb
Maximum load on cylinder 2 249930 lb
Maximum load on cylinder 3 250550 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.