Print Report | Back to Sample Detail

Sample Record for 2021-10-06-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215397 DEA: 042Q0504 EFIS: 0418000413 QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL-87,101,680-Var
Work Description: PLACE POLYESTER CONCRETE OVERLAY AND TREAT BRIDGE DECKS.
Location Description: SANTA CLARA COUNTY AT VARIOUS LOCATIONS
Contractor Name: TRUESDELL CORP OF CALIFORNIA INC
Contractor Address: 1310 W 23RD STREET, TEMPE AZ 85282
Resident Engineer: Minh Hinh Structure Rep.: Hellina Au

Sample Information

DIME Sample ID: 2021-10-06-6
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 10/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 10/06/2021
The quantity of what the sample constitutes: 1 tanker
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt

Material Information

Mfg. Lot Number(s): 1364594
Batch number: 1364594
Mix number: 1364594

Test Results

Test 1 of 6

DIME Test ID: 2021-10-06-6-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 114

Test 2 of 6

DIME Test ID: 2021-10-06-6-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 8.9964

Test 3 of 6

DIME Test ID: 2021-10-06-6-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 5
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.487 in
Sample 1 Ultimate strength 3652.5 psi
Sample 1 Thickness 0.257 in
Sample 1 Area 0.1252 in^2
Sample 1 Ultimate Strength Actual 457.293 lbs
Sample 1 percent elongation 57.29 %
Sample 1 Time 0 MM:SS
Sample 2 Width 0.487 in
Sample 2 Thickness 0.253 in
Sample 2 Area 0.1232 in^2
Sample 2 Ultimate strength 3567.3 psi
Sample 2 Ultimate Strength Actual 439.491 lbs
Sample 2 percent elongation 52.34 %
Sample 2 Time 0 MM:SS
Sample 3 Width 0.487 in
Sample 3 Thickness 0.255 in
Sample 3 Area 0.1242 in^2
Sample 3 Ultimate strength 3617.8 psi
Sample 3 Ultimate Strength Actual 449.331 lbs
Sample 3 percent elongation 55.32 %
Sample 3 Time 0 MM:SS
Sample 4 Width 0.487 in
Sample 4 Thickness 0.254 in
Sample 4 Area 0.1237 in^2
Sample 4 Ultimate strength 3690.9 psi
Sample 4 Ultimate Strength Actual 456.564 lbs
Sample 4 percent elongation 64.32 %
Sample 4 Time 0 MM:SS
Sample 5 Width 0.486 in
Sample 5 Thickness 0.255 in
Sample 5 Area 0.1239 in^2
Sample 5 Ultimate strength 3724.7 psi
Sample 5 Ultimate Strength Actual 461.49 lbs
Sample 5 percent elongation 64.61 %
Sample 5 Time 0 MM:SS
Ultimate Strength Average 3651 psi
Percent Elongation Average 59 %

Test 4 of 6

DIME Test ID: 2021-10-06-6-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 46.1

Test 5 of 6

DIME Test ID: 2021-10-06-6-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1495.57 lb
Span length for Sample 1 9 in
Break location for Sample 1 PCC
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 747.787 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1719.24 lb
Span length for Sample 2 9 in
Break location for Sample 2 PCC
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 859.622 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1623.33 lb
Span length for Sample 3 9 in
Break location for Sample 3 PCC
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 811.665 psi

Test 6 of 6

DIME Test ID: 2021-10-06-6-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 75 f
Tare weight 0 grams
Initial weight 100 grams
Weight at 5 minutes 99.899 grams
Weight at 10 minutes 99.84 grams
Weight at 15 minutes 99.788 grams
Weight at 20 minutes 99.74 grams
Weight at 25 minutes 99.615 grams
Weight at 30 minutes 99.552 grams
Final weight 99.55 grams
Total weight loss 0.45 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 24.191 grams/m^2