Sample Record for 2021-09-29-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215417 DEA: 101K9304 EFIS: 1020000014 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-VAR,580-VAR
Work Description: BRIDGE DECKS INVESTIGATION AND REHABILITATION IN AND NEAR TRACY
Location Description: SJ CTY IN & NEAR TRACY FROM GAFFERY RD TO EAST MIDWAY
Contractor Name: Meyers & Sons
Contractor Address: Unknown
Resident Engineer: Bal Bahadur Paul Structure Rep.: Ron Matin

Sample Information

DIME Sample ID: 2021-09-29-5
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 09/29/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/29/2021
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt

Material Information

Mfg. Lot Number(s): 1361244
Batch number: 1361244
Mix number: 1361244

Test Results

Test 1 of 6

DIME Test ID: 2021-09-29-5-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 109

Test 2 of 6

DIME Test ID: 2021-09-29-5-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 8.9964

Test 3 of 6

DIME Test ID: 2021-09-29-5-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 5
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.486 in
Sample 1 Ultimate strength 3504.7 psi
Sample 1 Thickness 0.245 in
Sample 1 Area 0.1191 in^2
Sample 1 Ultimate Strength Actual 417.41 lbs
Sample 1 percent elongation 67.73 %
Sample 1 Time 0 MM:SS
Sample 2 Width 0.486 in
Sample 2 Thickness 0.243 in
Sample 2 Area 0.1181 in^2
Sample 2 Ultimate strength 3170.3 psi
Sample 2 Ultimate Strength Actual 374.412 lbs
Sample 2 percent elongation 58.97 %
Sample 2 Time 0 MM:SS
Sample 3 Width 0.486 in
Sample 3 Thickness 0.244 in
Sample 3 Area 0.1186 in^2
Sample 3 Ultimate strength 3620 psi
Sample 3 Ultimate Strength Actual 429.332 lbs
Sample 3 percent elongation 70.38 %
Sample 3 Time 0 MM:SS
Sample 4 Width 0.486 in
Sample 4 Thickness 0.244 in
Sample 4 Area 0.1186 in^2
Sample 4 Ultimate strength 3469.3 psi
Sample 4 Ultimate Strength Actual 411.459 lbs
Sample 4 percent elongation 67.12 %
Sample 4 Time 0 MM:SS
Sample 5 Width 0.486 in
Sample 5 Thickness 0.251 in
Sample 5 Area 0.122 in^2
Sample 5 Ultimate strength 3387.5 psi
Sample 5 Ultimate Strength Actual 413.275 lbs
Sample 5 percent elongation 65.33 %
Sample 5 Time 0 MM:SS
Ultimate Strength Average 3430 psi
Percent Elongation Average 66 %

Test 4 of 6

DIME Test ID: 2021-09-29-5-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 46

Test 5 of 6

DIME Test ID: 2021-09-29-5-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 2025.93 lb
Span length for Sample 1 9 in
Break location for Sample 1 PCC
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 1012.96 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 2040.01 lb
Span length for Sample 2 9 in
Break location for Sample 2 PCC
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 1020.01 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1664.23 lb
Span length for Sample 3 9 in
Break location for Sample 3 PCC
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 832.113 psi

Test 6 of 6

DIME Test ID: 2021-09-29-5-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/15/2021
Date Tested: 10/15/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Based On Supplier Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 75 f
Tare weight 0 grams
Initial weight 100 grams
Weight at 5 minutes 99.934 grams
Weight at 10 minutes 99.858 grams
Weight at 15 minutes 99.805 grams
Weight at 20 minutes 99.736 grams
Weight at 25 minutes 99.641 grams
Weight at 30 minutes 99.565 grams
Final weight 99.57 grams
Total weight loss 0.43 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 23.116 grams/m^2