Print Report | Back to Sample Detail

Sample Record for 2021-09-24-20

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215477 DEA: 081K6704 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-210-1.5/21.5
Work Description: FURNISH AND TREAT BRIDGE DECK AND REPLACE JOINT SEALS.
Location Description: SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-09-24-20
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: 760-518-6064
Type of Sample: Quality Control
Type of Material: Methacrylate
Sample Taken Date: 09/24/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/24/2021
The quantity of what the sample constitutes: 25000 gallons
A brief description of the sample: 2 pints 204,chp,zcure,8020
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers and Polynt

Material Information

Mfg. Lot Number(s): 2110890989
Batch number: 2110890989
Mix number: 2110890989

Test Results

Test 1 of 1

DIME Test ID: 2021-09-24-20-1
Test Method: CONCLP 4-16: HMWM
Verified Date: 10/08/2021
Date Tested: 10/08/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test: PCC-SSD Bond Strength Accepted Based On Supplier Results.
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F 21.25
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F 1.07
Volatile content (ASTM D 2369) 30% max 29.4
Flash point (ASTM D 3828) more than 180 deg F 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours 862
Tack free time, 400 minutes max 276

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.