Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215371 DEA: 042W1204 EFIS: 0421000139
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC,CC/MRN-580-6.9/7.8, 6.9, 7.8, 02, 5
Work Description: REPLACEMENT OF GUSSET PLATES AT VARIOUS LOCATIONS
Location Description: Richmond San Rafael Bridge
Contractor Name: FLATIRON WEST INC
Contractor Address: 2100 Goodyear Rd., Benicia, CA 94510
Resident Engineer: Behzad Halali Structure Rep.: William Sommer
DIME Sample ID: 2021-09-22-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/22/2021
The quantity of what the sample constitutes: 124 bolts
A brief description of the sample: A325 Bolt
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name: RSRB
The fabricator/manufacturer/facility name: LeJeune Bolt Company
Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): n/a
Bolt Specification: A325
Bolt Length(s): 8.5
Nut Specification: n/a
Washer Specification: n/a
Finish: MG
Diameter/Size: 1.125
Bolt Mfg. Lot Number: L722J1
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2021-09-22-17-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1 | L722J1 | 1.1250 | 101896 | 453.26 | 6.00 | A325 | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2021-09-22-17-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L722J1
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 LE USA
|
Size
|
1.125 in
|
Bolt Length
|
8.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-09-22-17-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L722J1
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 LE USA
|
Size
|
1.125 in
|
Bolt Length
|
8.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-09-22-17-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L722J1
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 LE USA
|
Size
|
1.125 in
|
Bolt Length
|
8.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-09-22-17-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L722J1
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 LE USA
|
Size
|
1.125 in
|
Bolt Length
|
8.5 in
|
Measurement Average
|
3.77 mils
|
DIME Test ID: 2021-09-22-17-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L722J1
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 LE USA
|
Size
|
1.125 in
|
Bolt Length
|
8.5 in
|
Measurement Average
|
3.64 mils
|
DIME Test ID: 2021-09-22-17-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/01/2021
Date Tested: 09/29/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L722J1
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 LE USA
|
Size
|
1.125 in
|
Bolt Length
|
8.5 in
|
Measurement Average
|
3.3 mils
|