Print Report | Back to Sample Detail

Sample Record for 2021-08-30-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215572 DEA: 032G1104 EFIS: 0320000230 QA Service Level: 1
DIST-CO-RTE-PM: 03-GLE-162-66.6/76.3
Work Description: PLACE RHMA AND COLD IN-PLACE RECYCLE.
Location Description: GLENN COUNTY IN AND NEAR WILLOWS FROM 0.2 MILE EAST OF N SHASTA STREET TO 1.0 MILE EAST OF ROAD X
Contractor Name: BALDWIN CONTRACTING CO., INC. DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 Skyway, CHICO, CA 95928
Resident Engineer: Dan Reechs Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-30-47
TL Number from the TL Form: c694338
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/30/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/17/2021
The quantity of what the sample constitutes: 1 gallon can
A brief description of the sample: Asphalt rubber binder
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pavement Coatings

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2021-08-30-47-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 05/31/2022
Date Tested: 09/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: does not comply
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 75 0.1 mm

Test 2 of 3

DIME Test ID: 2021-08-30-47-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/24/2021
Date Tested: 09/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 58 C
Softening Point Sample 2 58 C
Bath Liquid USP glycerin
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2021-08-30-47-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/24/2021
Date Tested: 09/24/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: does not comply
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 102 mm
Ball Penetration (P1) 6 mm
Final Dial reading (F2) 100 mm
Ball Penetration (P2) 7 mm
Final Dial reading (F3) 103 mm
Ball Penetration (P3) 7 mm
Resilience 1 4 %
Resilience 2 7 %
Resilience 3 4 %
Average Resilience 5 %
Minutes Reaction no data