STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 103A66U4 Cty MER Rte 140 PM 58.7/60.5

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Brent Haroldsen

Date Reported:

10/02/2014

Address:

TL Number:

City:

Project Name: BRIDGE REPLACEMENT AND WIDEN ROADWAY.

Prime Contractor: R G W CONSTRUCTION INC

Sample Taken Date:

08/21/2014

Mix Design:

585861

Contractor: Unknown

Location: MERCED COUNTY IN AND NEAR MERCED FROM MARTHELLA AVENUE TO 0.3 KM EAST OF SANTA FE AVENUE

Structure unique identifier:

Structure name: bradley over head

Location of Pour:


The following testing has been tested in accordance with:

ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Maximum load on cylinder (lb)Type of fracture pattern of cylinder
16.021024561
26.011022371

DIME Test ID: 2014-08-21-8-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3600
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 14 days
Certified By: Mike Mullins


ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenCross sectional area of cylinder (in^2)Average diameter of cylinder (in)Compressive strength of cylinder (psi)Maximum load on cylinder (lb)Type of fracture pattern of cylinder
128.466.024474.51273451
228.376.014381.71243081

DIME Test ID: 2014-08-21-8-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4430
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Mike Mullins


ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenCross sectional area of cylinder (in^2)Average diameter of cylinder (in)Compressive strength of cylinder (psi)Maximum load on cylinder (lb)Type of fracture pattern of cylinder
128.276.005045.51426361
228.276.004772.01349041

DIME Test ID: 2014-08-21-8-5
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4910
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 42 days
Certified By: Mike Mullins



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing