Project Information

Project ID: 215161 DEA: 010C5704 EFIS: 0113000009 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-69.8/75.2
Work Description: PLACE RHMA-G, HMA AND CONCRETE BARRIER.
Location Description: HUMBOLDT COUNTY IN AND NEAR EUREKA FROM 0.8 MILE SOUTH OF TOMPKINS HILL ROAD OVERHEAD TO 0.4 MILE NORTH OF HERRICK AVENUE OVERCROSSING
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: 77 2nd St, Eureka, CA 95501
Resident Engineer: Joaquin Rodriguez Structure Rep.: Jarred Burrows

Sample Information

DIME Sample ID: 2021-09-02-26
TL Number from the TL Form: c972623
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/02/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/09/2021
The quantity of what the sample constitutes: 2 cans
A brief description of the sample: PG64-16 Rubber Blend
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Plant B

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:

Test Results

Test 1 of 4

DIME Test ID: 2021-09-02-26-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/15/2021
Date Tested: 09/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 24 0.1 mm

Test 2 of 4

DIME Test ID: 2021-09-02-26-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/15/2021
Date Tested: 09/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 73 C
Softening Point Sample 2 73 C
Bath Liquid USP glycerin

Test 3 of 4

DIME Test ID: 2021-09-02-26-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/15/2021
Date Tested: 09/14/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 65 mm
Ball Penetration (P1) 1 mm
Final Dial reading (F2) 65 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F3) 67 mm
Ball Penetration (P3) 1 mm
Resilience 1 36 %
Resilience 2 36 %
Resilience 3 34 %
Average Resilience 35 %

Test 4 of 4

DIME Test ID: 2021-09-02-26-4
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/24/2021
Date Tested: 09/15/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified: pass
Determination Unworked Penetration
Unworked Penetration 25 0.1 mm

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.