Print Report | Back to Sample Detail

Sample Record for 2021-08-27-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215126 DEA: 010G33U4 EFIS: 0120000002 QA Service Level: 1
DIST-CO-RTE-PM: 01-LAK-20-5.1/6.3
Work Description: Widen shoulders and replace bridge with box culvert.
Location Description: LAKE COUNTY NEAR UPPER LAKE FROM 0.4 MILE WEST OF WITTER SPRINGS ROAD TO 0.4 MILE EAST OF BACHELOR CREEK BRIDGE
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: 1520 Fourth St., Berkeley, CA 94710
Resident Engineer: Katharine Perrin Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-27-26
TL Number from the TL Form:
Sample Submitted By Organization: Universal Precast Concrete - Redding
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/27/2021
The quantity of what the sample constitutes: 2
A brief description of the sample: conc. cylinder
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Precast Concrete

Material Information

The concrete mix design number: PC65A0E2
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 001434
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: back of truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2021-08-27-26-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/08/2021
Date Tested: 09/03/2021
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Apparent mass of submerged cylinder 1 29 lb
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4090 psi
Maximum load on cylinder 1 115990 lb
Maximum load on cylinder 2 115530 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Age of specimen 7 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Test 2 of 2

DIME Test ID: 2021-08-27-26-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/28/2021
Date Tested: 09/24/2021
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 29 lb
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Average diameter of cylinder 3 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Cross sectional area of cylinder 3 28.27 in^2
Compressive strength (to nearest 10 psi) 5140 psi
Maximum load on cylinder 1 141910 lb
Maximum load on cylinder 2 145550 lb
Maximum load on cylinder 3 148900 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Age of specimen 28 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data