DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 100S1104 Cty SJ Rte 4 PM Var Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Harminder Deol |
Date Reported: |
10/01/2014 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: SR-4 FREEWAY EXTENSION |
||||
Prime Contractor: BROSAMER & WALL, INC. |
||||
Sample Taken Date: |
08/20/2014 |
Mix Design: |
000000000000 |
|
Contractor: Unknown |
Location: IN SAN JOAQUIN COUNTY |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|
1 | 6.02 | 87562 | 1 |
2 | 6.02 | 90365 | 1 |
DIME Test ID: 2014-08-20-15-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3130
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 7 days
Certified By: Mike Mullins
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|
1 | 6.02 | 95637 | 1 |
2 | 6.02 | 106256 | 1 |
DIME Test ID: 2014-08-20-15-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3550
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 14 days
Certified By: Mike Mullins
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.46 | 6.02 | 4609.6 | 131190 | 1 |
2 | 28.46 | 6.02 | 4401.3 | 125261 | 1 |
DIME Test ID: 2014-08-20-15-3
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4510
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Bang Nguyen
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.46 | 6.02 | 5231.0 | 148874 | 1 |
2 | 28.56 | 6.03 | 5365.7 | 153244 | 1 |
DIME Test ID: 2014-08-20-15-8
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5300
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 42 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing