Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030F2864 Cty SAC Rte 99 PM 7.92 / 8.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Masoud Saed |
Date Reported: |
09/29/2021 |
|
Address: |
TL Number: |
293110 |
||
City: |
||||
Project Name: Remove and replace Consumnes River and Consumnes River Overflow bridge |
||||
Prime Contractor: GRANITE CONSTRUCTION COMPANY |
||||
Sample Taken Date: |
09/01/2021 |
Mix Design: |
201 |
|
Contractor: Unknown |
Location: Sacramento County |
|||
Structure unique identifier: |
||||
Structure name: River A1/A6 Backwall and shear key |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 77051 | 6071.0 | 1 |
2 | 4.03 | 12.76 | 74408 | 5833.0 | 1 |
3 | 4.02 | 12.69 | 76153 | 6000 | 1 |
DIME Test ID: 2021-09-01-17-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5970
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing