Print Report | Back to Sample Detail

Sample Record for 2021-08-27-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214532 DEA: 07316904 EFIS: 0715000227 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-1,2,5,10-Various
Work Description: TUNNEL LIGHTING, MESSAGE SIGN SYSTEMS, RETAINING WALL & BUILDING WORK.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS
Contractor Name: ALDRIDGE ELECTRIC, INC.
Contractor Address: 2369 Yates Ave, Commerce, CA 90040
Resident Engineer: Frank Shin Structure Rep.: Frank Lotfi

Sample Information

DIME Sample ID: 2021-08-27-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/31/2021
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0510-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond-Victorville

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2021-08-27-19-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/02/2021
Date Tested: 09/02/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 51 0.1 mm

Test 2 of 3

DIME Test ID: 2021-08-27-19-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/03/2021
Date Tested: 09/01/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 56 C
Softening Point Sample 2 56 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2021-08-27-19-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/02/2021
Date Tested: 09/02/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 82 mm
Ball Penetration (P1) 4 mm
Final Dial reading (F2) 82 mm
Ball Penetration (P2) 3 mm
Final Dial reading (F3) 82 mm
Ball Penetration (P3) 4 mm
Resilience 1 22 %
Resilience 2 21 %
Resilience 3 22 %
Average Resilience 22 %
Minutes Reaction no data