Print Report | Back to Sample Detail

Sample Record for 2021-08-31-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215494 DEA: 081H4904 EFIS: 0817000059 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-18-31.9/38.5
Work Description: COLD PLANE AC PAVEMENT AND OVERLAY WITH HMA (TYPE A).
Location Description: SAN BERNARDINO COUNTY FROM 0.1 MILE EAST OF HILLTOP CONNECTOR TO 0.5 MILE EAST OF SIBERIA CREEK TRAIL
Contractor Name: Matich Corp
Contractor Address: P.O. Box 10, Highland, CA 92346-1010
Resident Engineer: Nhan Nguyen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-08-31-15
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/31/2021
Date that the sample was received by the laboratory/organization performing the testing: 09/01/2021
The quantity of what the sample constitutes: 2 boxes 672.54 tons out
A brief description of the sample: 3/4" HMA-A SP R12 0.75% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0515A-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Matich Lytle Creek

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2021-08-31-15-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/09/2021
Date Tested: 09/02/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.68 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2021-08-31-15-1AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)09/01/2021Not scheduledCristina ParedesCT D08 - Fontana Southern Regional Laboratory