Print Report | Back to Sample Detail

Sample Record for 2021-08-26-22

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214919 DEA: 060U4504 EFIS: 0615000298 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-168-18.6/T25.5
Work Description: COLD PLANE AC PAVEMENT AND HOT MIX ASPHALT RESURFACING.
Location Description: FRESNO COUNTY NEAR PRATHER FROM 0.1 MILE EAST OF SAMPLE ROAD TO OAK CREEK ROAD
Contractor Name: Cal Valley Construction
Contractor Address: 5125 N. Gates Ave., Ste. 102, Fresno, CA, 93722-6414
Resident Engineer: Mark Mengoni Structure Rep.: Raman Guraya

Sample Information

DIME Sample ID: 2021-08-26-22
TL Number from the TL Form: 039820
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/27/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: JMF
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Pittsburg

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2021-08-26-22-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/02/2021
Date Tested: 09/01/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: 2018 per spec.
Test Result Compliance:
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 29 0.1 mm

Test 2 of 4

DIME Test ID: 2021-08-26-22-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 09/02/2021. The corrected test ID is: 2021-08-26-22-4
Reason: retested

Test 3 of 4

DIME Test ID: 2021-08-26-22-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/02/2021
Date Tested: 08/31/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 76 mm
Ball Penetration (P1) 0 mm
Final Dial reading (F2) 76 mm
Ball Penetration (P2) 0 mm
Final Dial reading (F3) 74 mm
Ball Penetration (P3) 0 mm
Resilience 1 24 %
Resilience 2 24 %
Resilience 3 26 %
Average Resilience 25 %
Minutes Reaction no data

Test 4 of 4

DIME Test ID: 2021-08-26-22-4
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/02/2021
Date Tested: 08/31/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
The test was superseded from test ID: 2021-08-26-22-2
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 74 C
Softening Point Sample 2 74 C
Bath Liquid USP glycerin
Minutes Reaction no data