Print Report | Back to Sample Detail

Sample Record for 2021-08-12-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214919 DEA: 060U4504 EFIS: 0615000298 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-168-18.6/T25.5
Work Description: COLD PLANE AC PAVEMENT AND HOT MIX ASPHALT RESURFACING.
Location Description: FRESNO COUNTY NEAR PRATHER FROM 0.1 MILE EAST OF SAMPLE ROAD TO OAK CREEK ROAD
Contractor Name: Cal Valley Construction
Contractor Address: 5125 N. Gates Ave., Ste. 102, Fresno, CA, 93722-6414
Resident Engineer: Mark Mengoni Structure Rep.: Raman Guraya

Sample Information

DIME Sample ID: 2021-08-12-28
TL Number from the TL Form: 040579
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 08/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/20/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: PG 64-16
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refinery

Material Information

Performance Grade: PG 64-16
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2021-08-12-28-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 09/03/2021
Date Tested: 08/26/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: as per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 172.630 grams
Mass of empty container #2 167.193 grams
Mass of container #1 before test (m1i) 207.937 grams
Mass of container #2 before test (m2i) 202.606 grams
Mass of container #1 after test (m1f) 207.941 grams
Mass of container #2 after test (m2f) 202.613 grams
Average mass change 0.016 percent

Test 2 of 5

DIME Test ID: 2021-08-12-28-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/03/2021
Date Tested: 08/26/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 standard specifications OG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.169 kPa
Phase Angle (δ) (for the 10 cycles) 89.3 degree
Complex Modulus (G*) (for the 10 measurements) 1.409 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 1.41 kPa

Test 3 of 5

DIME Test ID: 2021-08-12-28-3
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/03/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 standard specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.269 kPa
Phase Angle (δ) (for the 10 cycles) 88.2 degree
Complex Modulus (G*) (for the 10 measurements) 2.694 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 2.70 kPa

Test 4 of 5

DIME Test ID: 2021-08-12-28-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/03/2021
Date Tested: 08/31/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 standard specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 52.989 kPa
Phase Angle (δ) (for the 10 cycles) 60.2 degree
Complex Modulus (G*) (for the 10 measurements) 5298.900 kPa
Test Temperature (Specimen 1) 28.0 C
(G*) x sin(δ)= 4598 kPa

Test 5 of 5

DIME Test ID: 2021-08-12-28-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 09/03/2021
Date Tested: 08/31/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s -6.0 C
Maximum test bath temperature at 240 s -6.0 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) 0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 0.0 mN
Deflection at time 0.0 s 0.000 µm
Load at time 0.5 s 0.0 mN
Deflection at time 0.5 s 0.000 µm
Load at 60.0 s 992.0 mN
Beam deflection 60.0 s 0.417 µm
Measured Stiffness Modulus 60.0 s 192.000 mPa
Estimated Stiffness Modulus 60.0 s 192.000 mPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.398