Project ID: 214114 DEA: 040A5394 EFIS: 0418000244
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80,12-11.4/12.8, 2.1/2.8
Work Description: Widen EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc.
Location Description: I-80/I-680/Route 12 Interchange
Contractor Name: Kiewit Infrastructure West Co.
Contractor Address: 4650 Business Center Drive, Fairfield, CA 94534
Resident Engineer: Cassaundra Lograsso Structure Rep.: Kambiz Kouchesfahani
DIME Sample ID: 2021-07-21-53
TL Number from the TL Form:
Sample Submitted By Organization: Construction Testing Services
Sample Organization Contact: (925) 351-6905
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/22/2021
The quantity of what the sample constitutes: 1 Day of Production
A brief description of the sample: 6000 PSI Concrete
From where was the sample collected: Job Site
Laboratory sample identification: 233300
Structure unique identifier:
Structure name: Separation Bridge
The fabricator/manufacturer/facility name: Cemex
The concrete mix design number: 1619340
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 29755368
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2021-07-21-53-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap
Verified Date: 08/23/2021
Date Tested: 08/18/2021
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Compressive strength (to nearest 10 psi)
|
7460 psi
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Maximum load on cylinder 1
|
222858 lb
|
Maximum load on cylinder 2
|
198847 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|