Print Report | Back to Sample Detail

Sample Record for 2021-08-10-25

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214573 DEA: 073096U4 EFIS: 0719000091 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R0.0/R9.7
Work Description: PLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location Description: LOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 15335 FAIRFIELD RANCH ROAD, CHINO HILLS, CA 91709
Resident Engineer: Ridwan Salman Structure Rep.: Adriana Pimienta

Sample Information

DIME Sample ID: 2021-08-10-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/10/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/11/2021
The quantity of what the sample constitutes: 10CY
A brief description of the sample: JPCP beams
From where was the sample collected: Source
Laboratory sample identification: 21-1993
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Flatiron Plant

Material Information

The concrete mix design number: JPCP-3215-06
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 23
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bobcat on site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2021-08-10-25-1CTM 523-July 2012: Method of Test for Flexural Strength of Concrete08/21/202108/20/2021Chad ChotibhongsCT D07 - Materials Field Laboratory, Unit 1953You can try with the data that I just send in email to RE today.Nelson Alvarado
2021-08-10-25-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method08/21/202108/10/2021Chad ChotibhongsCT D07 - Materials Field Laboratory, Unit 1953You can try with the data that I just send email to RE today.Nelson Alvarado
2021-08-10-25-3CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete08/21/202108/10/2021Chad ChotibhongsCT D07 - Materials Field Laboratory, Unit 1953You can try with the data that I just send email to RE today.Nelson Alvarado