Sample Record for 2021-08-20-9
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215371 DEA: 042W1204 EFIS: 0421000139
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC,CC/MRN-580-6.9/7.8, 6.9, 7.8, 02, 5
Work Description: REPLACEMENT OF GUSSET PLATES AT VARIOUS LOCATIONS
Location Description: Richmond San Rafael Bridge
Contractor Name: FLATIRON WEST INC
Contractor Address: 2100 Goodyear Rd., Benicia, CA 94510
Resident Engineer: Behzad Halali Structure Rep.: William Sommer
Sample Information
DIME Sample ID: 2021-08-20-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/20/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/25/2021
The quantity of what the sample constitutes: 600
A brief description of the sample: 1-1/8x4-1/4 A325 HSB Assy - washer
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: RSRB
The fabricator/manufacturer/facility name: LeJeune Bolt Company
Material Information
Rocap Number(s): L1414447
Heat Number(s): x1450
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): D7721
Bolt Specification: na
Bolt Length(s): na
Nut Specification: na
Washer Specification: ASTM F436 M/G
Finish: ASTM B695 Class 55-1 Mech Galv
Diameter/Size: 1-1/8 inch
Bolt Mfg. Lot Number: na
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 8
DIME Test ID: 2021-08-20-9-1
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.26 mils
|
Test 2 of 8
DIME Test ID: 2021-08-20-9-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.94 mils
|
Test 3 of 8
DIME Test ID: 2021-08-20-9-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.17 mils
|
Test 4 of 8
DIME Test ID: 2021-08-20-9-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.9 mils
|
Test 5 of 8
DIME Test ID: 2021-08-20-9-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.97 mils
|
Test 6 of 8
DIME Test ID: 2021-08-20-9-6
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39
|
Spacing
|
Ok
|
Test 7 of 8
DIME Test ID: 2021-08-20-9-7
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.15
|
Spacing
|
Ok
|
Test 8 of 8
DIME Test ID: 2021-08-20-9-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/31/2021
Date Tested: 08/27/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7721
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
F436 P
|
Size
|
1.125 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
38.1
|
Spacing
|
Ok
|