Sample Record for 2021-08-07-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214665 DEA: 081G5504 EFIS: 0816000035
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R28.9
Work Description: REPLACE WEIGH-IN-MOTION SYSTEM WITH HIGH SPEED WEIGH-IN-MOTION SYSTEM.
Location Description: SAN BERNARDINO COUNTY NEAR NEWBERRY SPRINGS AT 3.6 MILES WEST OF HECTOR ROAD UNDERCROSSING
Contractor Name: Global Road Sealing Inc
Contractor Address: 10832 Dorothy Ave, Garden Grove, CA, 92843
Resident Engineer: Thanh Pham Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2021-08-07-4
TL Number from the TL Form: 1034-87
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/07/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2021
The quantity of what the sample constitutes: 2 Cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Other
Laboratory sample identification: 1034-87
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Short Load Concrete Inc
Material Information
The concrete mix design number: CTS-65-EHI
The truck number from where the sample was collected: Not Provided
The batch plant ticket number from where the sample was collected: Not Provided
Concrete batch plant: Not Provided
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Not Provided
Where the material sample would have been placed if not sampled: Not Provided
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2021-08-07-4-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/17/2021
Date Tested: 08/14/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: Tested at 8:30PM.
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Average diameter of cylinder 1
|
5.98 in
|
Average diameter of cylinder 2
|
5.97 in
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Cross sectional area of cylinder 1
|
28.09 in^2
|
Cross sectional area of cylinder 2
|
27.99 in^2
|
Compressive strength (to nearest 10 psi)
|
5710 psi
|
Maximum load on cylinder 1
|
160280 lb
|
Maximum load on cylinder 2
|
159990 lb
|
Compressive strength of cylinder 1
|
5705.9 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
5716.0 psi
|
Type of fracture pattern of cylinder 2
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
0 hours
|