Print Report | Back to Sample Detail

Sample Record for 2021-08-05-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215359 DEA: 081K1904 EFIS: 0818000207 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-16.1/169.4
Work Description: REMOVE, PREPARE AND FURNISH POLYESTER CONC OVERLAY & BRIDGE DECK.
Location Description: SAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT VARIOUS LOCATIONS FROM CAJON CREEK TO MICRO DITCH.
Contractor Name: VELARDE CONCRETE CONSTRUCTION
Contractor Address: 523 S. BRAND BLVD, SAN FERNANDO CA 91340
Resident Engineer: Thanh Pham Structure Rep.: Monty Navarro

Sample Information

DIME Sample ID: 2021-08-05-7
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/05/2021
Date that the sample was received by the laboratory/organization performing the testing: 08/05/2021
The quantity of what the sample constitutes: 2
A brief description of the sample: concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1030-85
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: GL THROOP

Material Information

The concrete mix design number: 2007-007
The truck number from where the sample was collected: NP
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Cajon Creek
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2021-08-05-7-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/02/2021
Date Tested: 09/02/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.01 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 6190 psi
Maximum load on cylinder 1 176350 lb
Maximum load on cylinder 2 175220 lb
Compressive strength of cylinder 1 6196.4 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 6176.2 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 0 hours