Project ID: 215411 DEA: 060X1904 EFIS: 0618000230
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,KIN-5,41,168,180,198-Var
Work Description: PLACE POLYESTER CONCRETE OVERLAY, REPLACE JOINT SEALS AND TREAT DECK.
Location Description: FRESNO AND KINGS COUNTIES AT VARIOUS LOCATIONS
Contractor Name: Myers & Sons Construction
Contractor Address: 4600 Northgate Boulevard, Suite 100, Sacramento, CA 95834-1121
Resident Engineer: Edmund Amobi Structure Rep.: Ramandeep Guraya
DIME Sample ID: 2021-07-22-36
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 594-1991
Type of Sample: Quality Assurance
Type of Material: Methacrylate
Sample Taken Date: 07/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/22/2021
The quantity of what the sample constitutes: 1 gallon can
A brief description of the sample: 1 gallon can
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Myers and Sons
DIME Test ID: 2021-07-22-36-1
Test Method: CONCLP 4-16: HMWM
Verified Date: 08/04/2021
Date Tested: 08/04/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted tack free time based on suppliers results. PCC Bond Strength not performed due to material being tested for recertification.
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F
|
21.76
|
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F
|
0.91
|
Volatile content (ASTM D 2369) 30% max
|
18.28
|
Flash point (ASTM D 3828) more than 180 deg F
|
220
|
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours
|
no data psi
|
Tack free time, 400 minutes max
|
210
|