Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215483 DEA: 022J0004 EFIS: 0221000017
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-49-0.0/7.5
Work Description: PLACE HOT MIX ASPHALT (TYPE A).
Location Description: PLUMAS COUNTY AT AND NEAR VINTON FROM SIERRA COUNTY LINE TO ROUTE 70
Contractor Name: ALL AMERICAN CONSTRUCTION
Contractor Address: P.O. BOX 635 2048 PASEO ROAD, LIVE OAK CA 95953
Resident Engineer: Daniel Gibbs Structure Rep.: Unknown
DIME Sample ID: 2021-07-22-34
TL Number from the TL Form: 996940
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/23/2021
The quantity of what the sample constitutes: PSE 16 boxs
A brief description of the sample: 3/4 HMA-A 15rap PG64-10 Valero
From where was the sample collected: Manufacturer
Laboratory sample identification: D78909
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western NV Materials, Spanish Springs
DIME Test ID: 2021-07-22-34-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/09/2021
Date Tested: 07/26/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7336.6 grams
|
Mass of oven-dry sample in air for Sample 1
|
2601.1 grams
|
Mass of container filled with the sample and water for Sample 1
|
8887.5 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.477
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2021-07-22-34-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/09/2021
Date Tested: 07/26/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity
|
2.379
|
Bulk Specific Gravity 2
|
2.376
|
Bulk Specific Gravity 3
|
2.378
|
Average Bulk Specific Gravity
|
2.378
|
DIME Test ID: 2021-07-22-34-3
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/09/2021
Date Tested: 07/30/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
SI Units
|
Average Dry Tensile Strength
|
201 psi
|
Average Wet Tensile Strength
|
186 psi
|
Tensile Strength Ratio
|
0.93
|
DIME Test ID: 2021-07-22-34-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/09/2021
Date Tested: 08/03/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
no data
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
Mass of HMA Sample prior to ignition
|
1343.6 g
|
Corrected Asphalt Binder Content
|
5.42 %
|
Mass Loss
|
no data
|
Mass of aggregate remaining after ignition
|
1267.8 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.22 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000 F
|
DIME Test ID: 2021-07-22-34-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/09/2021
Date Tested: 07/27/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
4.0 %
|
Percent Air Voids 2
|
4.1 %
|
Percent Air Voids 3
|
4.0 %
|
Percent Air Voids Average
|
4.0 %
|