Print Report | Back to Sample Detail

Sample Record for 2021-05-19-39

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215252 DEA: 021J4704 EFIS: 0220000082 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-46.7/49.8,63.8/67.704
Work Description: HMA OVERLAY, REPLACE AC SURFACING AND SHOULDER BACKING.
Location Description: TRINITY COUNTY NEAR TRINITY CENTER FROM 0.7 MILE NORTH OF CEDAR STOCK ROAD TO DIENER MINE VIADUCT AND FROM 2.3 MILES NORTH OF EL DORADO WAY TO COFFEE CREEK BRIDGE NO. 05-0060
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 17400 CLEAR CREEK RD, REDDING CA 96001
Resident Engineer: Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-19-39
TL Number from the TL Form: 002574
Sample Submitted By Organization: CT D02 - North Region Materials Lab
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 05/19/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2021
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: Combined Treated Virgin 3/8-inch Type A Aggreagte
From where was the sample collected: Manufacturer
Laboratory sample identification: D78805A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JF Shea Construction - Fawndale Rock and Asphalt - Redding, CA

Material Information

Source Identification (SMARA or name of Pit): 91-45-0017
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Cold Feed
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number: JMF 20-13-P01
Lot number:
Sublot number:

Test Results

Test 1 of 1

DIME Test ID: 2021-05-19-39-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/26/2021
Date Tested: 05/20/2021
Submitted By Organization: CT D02 - North Region Materials Lab
Organization Address: 1657 Riverside Dr,MS-83
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type) Yes
Total mass of material in the sample 8240.3 grams
Cumulative mass retained on the 1 1/2 in. sieve 0 grams
Cumulative mass retained on the 1 in. sieve 0 grams
Cumulative mass retained on the 3/4 in. sieve 0 grams
Cumulative mass retained on the 1/2 in. sieve 11 grams
Cumulative mass retained on the 3/8 in. sieve 406 grams
Mass retained on the 1/4 in. sieve 2181 grams
Cumulative mass retained on the #4 sieve 3312 grams
Total sample mass passing the #4 sieve 4928.3 grams
Total mass of fine material in the sample 517.4 grams
Cumulative mass retained on the #8 sieve 245.7 grams
Cumulative mass retained on the #16 sieve 363.3 grams
Cumulative mass retained on the #30 sieve 422.5 grams
Cumulative mass retained on the #50 sieve 452.8 grams
Cumulative mass retained on the #100 sieve 469.4 grams
Cumulative mass retained on the #200 sieve 479.2 grams
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99.9 %
Cumulative percent passing the 3/8 in. sieve 95.1 %
Cumulative percent passing the 1/4 in. sieve 73.5 %
Cumulative percent passing the #4 sieve 59.8 %
Cumulative percent passing the #8 sieve 31.4 %
Cumulative percent passing the #16 sieve 17.8 %
Cumulative percent passing the #30 sieve 11 %
Cumulative percent passing the #50 sieve 7.5 %
Cumulative percent passing the #100 sieve 5.5 %
Cumulative percent passing the #200 sieve 4.42 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.