Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214926 DEA: 010E7204 EFIS: 0115000003
QA Service Level: 1
DIST-CO-RTE-PM: 01-LAK-29-12.7/14.5
Work Description: ROADWAY EXCAVATION, HMA (TYPE A), RHMA-G, DRAINAGE & EROSION CONTROL.
Location Description: LAKE COUNTY NEAR LOWER LAKE FROM 0.8 MILE NORTH OF SPRUCE GROVE ROAD SOUTH TO 0.4 MILE SOUTH OF HOFACKER LANE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC.
Contractor Address: 246 GHILOTTI AVENUE, SANTA ROSA, CA 95407
Resident Engineer: Dan Kraft Structure Rep.: Unknown
DIME Sample ID: 2021-07-12-39
TL Number from the TL Form: c724975
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 07/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: PG64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bodean - Santa Rosa
Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: BoDean - Santa Rosa
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-07-12-39-1
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/28/2021
Date Tested: 07/25/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications Original DSR
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.185 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
85.4 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.542 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.55 kPa
|
DIME Test ID: 2021-07-12-39-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/28/2021
Date Tested: 07/26/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO DSR
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.446 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
80.1 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
4.457 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
4.52 kPa
|
DIME Test ID: 2021-07-12-39-3
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/28/2021
Date Tested: 07/25/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
179.025 grams
|
Mass of empty container #2
|
177.008 grams
|
Mass of container #1 before test (m1i)
|
214.396 grams
|
Mass of container #2 before test (m2i)
|
212.534 grams
|
Mass of container #1 after test (m1f)
|
214.285 grams
|
Mass of container #2 after test (m2f)
|
212.420 grams
|
Average mass change
|
-0.317 percent
|