Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 7613 DEA: 071218W4 EFIS: 0700021119
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-29.4/31.6
Work Description: REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location Description: LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Vladimir Gurfinkel Structure Rep.: Gon Choi
DIME Sample ID: 2021-07-21-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 07/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/26/2021
The quantity of what the sample constitutes: 2 Coils
A brief description of the sample: 0.6" prestress steel strands
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Schwager-Davis
Comments:
Reel/Coil/Pack Number(s): 0647, 0651
Number of Coils: 2
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): 23402
Mfg. Lot Number(s): 23402
Manufacturer(s): Schwager Davis Inc
DIME Test ID: 2021-07-21-4-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 08/02/2021
Date Tested: 07/30/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 23402 | 1302464130647 | 0.216 | 60653 | 55329.5 | 28.6 | 1.84 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2021-07-21-4-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 08/02/2021
Date Tested: 07/30/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 23402 | 1302464130651 | 0.216 | 60157 | 55255.4 | 28.2 | 1.66 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|