Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215607 DEA: 061C6504 EFIS: 0621000099
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-41-R0.5/M5.9
Work Description: RESURFACE AC PAVEMENT AND INSTALL MEDIAN TYPE K CONCRETE BARRIER.
Location Description: FRESNO COUNTY ABOUT 6 MILES NORTH OF LEMOORE FROM 0.5 MILE NORTH OF EXCELSIOR AVENUE UNDERCROSSING TO 0.2 MILE SOUTH OF ELKHORN AVENUE
Contractor Name: Cal Valley Construction
Contractor Address: 5125 N. Gates Ave., Ste. 102, Fresno, CA, 93722-6414
Resident Engineer: Mark Mengoni Structure Rep.: Unknown
DIME Sample ID: 2021-07-15-21
TL Number from the TL Form: 039897
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 07/15/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2021
The quantity of what the sample constitutes: 1 OF 1 CAN
A brief description of the sample: BINDER 64-16
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refining Co Inc
Performance Grade: PG 64-16
Modified: No
Lot number: 2
Sublot number: 13
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-07-15-21-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/28/2021
Date Tested: 07/25/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications OG
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.170 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
89.3 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.415 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.42 kPa
|
DIME Test ID: 2021-07-15-21-3
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/28/2021
Date Tested: 07/25/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.286 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
88.3 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
2.859 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
2.86 kPa
|
DIME Test ID: 2021-07-15-21-4
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/28/2021
Date Tested: 07/25/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
174.664 grams
|
Mass of empty container #2
|
181.943 grams
|
Mass of container #1 before test (m1i)
|
210.225 grams
|
Mass of container #2 before test (m2i)
|
217.814 grams
|
Mass of container #1 after test (m1f)
|
210.135 grams
|
Mass of container #2 after test (m2f)
|
217.720 grams
|
Average mass change
|
-0.258 percent
|