Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Work Description: REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location Description:
Contractor Name: J McLoughlin Engineering
Contractor Address: 10641 Fulton Court, Rancho Cucamonga, CA 91730
Resident Engineer: Mujahid Qureshi Structure Rep.: Ching Chuang
DIME Sample ID: 2021-06-12-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2021
The quantity of what the sample constitutes: 2 boxes, 3 core
A brief description of the sample: 3/4" PG-64-16RB #226108
From where was the sample collected: Manufacturer
Laboratory sample identification: 2A31,2B31,2C31
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Corona
DIME Test ID: 2021-06-12-3-1
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/13/2021
Date Tested: 07/06/2021
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.311
|
Bulk Specific Gravity 2
|
2.31
|
Bulk Specific Gravity 3
|
2.281
|
Average Bulk Specific Gravity
|
2.301
|
DIME Test ID: 2021-06-12-3-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/13/2021
Date Tested: 07/06/2021
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Water
|
Specific Gravity for Sample 1
|
2.423
|
Theoretical maximum density at 25°C (77°F)
|
no data
|