Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214922 DEA: 100X3104 EFIS: 1013000265
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-99-16.8/17.6
Work Description: REPLACE BRIDGE.
Location Description: SAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING
Contractor Name: BRIDGEWAY CIVIL CONSTRUCTORS, INC.
Contractor Address: 3333 Vaca Valley Parkway, Suite 200, Vacaville, CA 95219
Resident Engineer: David Abledu Structure Rep.: Daniel Laureno
DIME Sample ID: 2021-07-08-6
TL Number from the TL Form: na
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/08/2021
Date that the sample was received by the laboratory/organization performing the testing: 07/08/2021
The quantity of what the sample constitutes: 380
A brief description of the sample: All Thread Rod
From where was the sample collected: Fabricator
Laboratory sample identification: na
Structure unique identifier:
Structure name: na
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc
Rocap Number(s): na
Heat Number(s): 10656870
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: A449
Bolt Length(s): 8"
Nut Specification: na
Washer Specification: na
Finish: HGD
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: 33988
Rocap Test Requirement(s): na
Lubricant Requirements(s): na
DIME Test ID: 2021-07-08-6-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/21/2021
Date Tested: 07/20/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1A | UNC 5/8 | 0.226 | 30732 | 136 | 135980 | 126773 | 28651 | A449 Tensile |
| |
UTM
|
400kip
|
Temperature
|
72
|
DIME Test ID: 2021-07-08-6-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 07/21/2021
Date Tested: 07/20/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1B | UNC 5/8 | 0.226 | 31364 | 139 | 138777 | 130454 | 29483 | A449 Tensile |
| |
UTM
|
400kip
|
Temperature
|
72
|
DIME Test ID: 2021-07-08-6-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-07-08-6-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-07-08-6-5
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-07-08-6-6
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-07-08-6-7
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Gage Type
|
Pass
|
DIME Test ID: 2021-07-08-6-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Measurement Average
|
2.64 mils
|
DIME Test ID: 2021-07-08-6-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Measurement Average
|
4.68 mils
|
DIME Test ID: 2021-07-08-6-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Measurement Average
|
2.62 mils
|
DIME Test ID: 2021-07-08-6-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Measurement Average
|
2.93 mils
|
DIME Test ID: 2021-07-08-6-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/21/2021
Date Tested: 07/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
10656870
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A449 01AE
|
Size
|
.625 in
|
Bolt Length
|
8 in
|
Measurement Average
|
3.57 mils
|