Print Report | Back to Sample Detail

Sample Record for 2021-06-28-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215607 DEA: 061C6504 EFIS: 0621000099 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-41-R0.5/M5.9
Work Description: RESURFACE AC PAVEMENT AND INSTALL MEDIAN TYPE K CONCRETE BARRIER.
Location Description: FRESNO COUNTY ABOUT 6 MILES NORTH OF LEMOORE FROM 0.5 MILE NORTH OF EXCELSIOR AVENUE UNDERCROSSING TO 0.2 MILE SOUTH OF ELKHORN AVENUE
Contractor Name: Cal Valley Construction
Contractor Address: 5125 N. Gates Ave., Ste. 102, Fresno, CA, 93722-6414
Resident Engineer: Mark Mengoni Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-06-28-10
TL Number from the TL Form: c039641
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphaltic Emulsion
Sample Taken Date: 06/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/30/2021
The quantity of what the sample constitutes: 1 of 1 jug
A brief description of the sample: SS-1h
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Standard Emulsions - Visalia

Material Information

Emulsion Grade: SS-1h
Lot Number:
Sub Lot:

Test Results

Test 1 of 1

DIME Test ID: 2021-06-28-10-1
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Verified Date: 07/01/2021
Date Tested: 07/01/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 per Standard specifications
Test Result Compliance:
Additional Comments When Verified: TL101 did not specified dilution info., residue is low and does not meet minimum requirement if its 100 pure.
How many beakers will be used to conduct the test? 4
Beaker 1 Residue 37.0 %
Beaker 2 Residue 38.2 %
Beaker 3 Residue 39.2 %
Beaker 4 Residue 38.0 %
Percentage of residue 38.0 %