Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214618 DEA: 033F99U4 EFIS: 0319000311
QA Service Level: 1
DIST-CO-RTE-PM: 03-SUT-99-39.2/41.4
Work Description: WIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location Description: SUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
Contractor Name: DESILVA GATES CONSTRUCTION
Contractor Address: 3855 N Freeway Blvd. , Ste 105, Sacramento, CA 95834
Resident Engineer: Dwayne Grandy Structure Rep.: Unknown
DIME Sample ID: 2021-06-16-16
TL Number from the TL Form: 706335
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 06/16/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/21/2021
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: PG58-22
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Benicia
Performance Grade: PG 58-22
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: DeSilva Gates
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-06-16-16-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/15/2021
Date Tested: 07/13/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
171.431 grams
|
Mass of empty container #2
|
165.576 grams
|
Mass of container #1 before test (m1i)
|
206.516 grams
|
Mass of container #2 before test (m2i)
|
201.983 grams
|
Mass of container #1 after test (m1f)
|
206.371 grams
|
Mass of container #2 after test (m2f)
|
201.831 grams
|
Average mass change
|
-0.415 percent
|
DIME Test ID: 2021-06-16-16-2
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/15/2021
Date Tested: 07/13/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications ORG
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.239 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
84.9 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.989 kPa
|
Test Temperature (Specimen 1)
|
58.0 C
|
Dynamic Shear, G*/sin(δ)
|
2.00 kPa
|
DIME Test ID: 2021-06-16-16-3
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/15/2021
Date Tested: 07/13/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.480 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
80.5 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
4.796 kPa
|
Test Temperature (Specimen 1)
|
58.0 C
|
Dynamic Shear, G*/sin(δ)
|
4.86 kPa
|
DIME Test ID: 2021-06-16-16-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/15/2021
Date Tested: 07/14/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Test Gap
|
2 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
1.00 %
|
Stress Amplitude
|
56.804 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
46.4 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
5,679.409 kPa
|
Test Temperature (Specimen 1)
|
22.0 C
|
(G*) x sin(δ)=
|
4113 kPa
|
DIME Test ID: 2021-06-16-16-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 07/15/2021
Date Tested: 07/14/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s
|
-12.0 C
|
Maximum test bath temperature at 240 s
|
-11.9 C
|
Time of test load application
|
no data HH:MM:SS
|
File name of test data
|
no data
|
Time beam in bath
|
no data
|
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
no data0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
981.0 mN
|
Beam deflection 60.0 s
|
0.664 µm
|
Measured Stiffness Modulus 60.0 s
|
119.000 mPa
|
Estimated Stiffness Modulus 60.0 s
|
119.000 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.355
|