Print Report | Back to Sample Detail

Sample Record for 2021-05-26-43

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215814 DEA: 023H3204 EFIS: 0217000097 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-5-2.7/R15.9
Work Description: Dunsmuir GAP - Pavement Rehabilitation.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-26-43
TL Number from the TL Form: 897758
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Preliminary
Type of Material: Soil
Sample Taken Date: 05/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/27/2021
The quantity of what the sample constitutes: 1 Container for Culvert Recommendation
A brief description of the sample: Soil
From where was the sample collected: Source
Laboratory sample identification: D78810
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: 02-SIS 5 PM 8.67 SB On Ramp 0.5 ft Depth
Where the material sample would have been placed if not sampled: 02 SIS 5

Test Results

Test 1 of 1

DIME Test ID: 2021-05-26-43-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 08/06/2021
Date Tested: 06/14/2021
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 13903.75 Ohm-cm
Minimum soil resistivity at 15.5 13904 Ohm-cm
Minimum soil resistance of the lab measurement 12250 Ohms
Soil sample temperature 20.9 C
pH of soil 6.30