Project Information

Project ID: 214339 DEA: 081G0004 EFIS: 0815000107 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-95-14.5/35.6
Work Description: CONSTRUCT CONCRETE/RSP APRONS
Location Description: RIVERSIDE COUNTY AT VARIOUS LOCATIONS FROM 4 MILES NORTH OF PALO VERDE DAM ROAD TO 0.6 MILE SOUTH OF SAN BERNARDINO COUNTY LINE
Contractor Name: Dreambuilder Construction Corporation
Contractor Address: 18543 Yorba Linda Blvd #376, Yorba Linda, CA 92886
Resident Engineer: Hien Vu Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-22-37
TL Number from the TL Form:
Sample Submitted By Organization: Pro-Cast Products Inc.
Sample Organization Contact: (909) 793-7602
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 04/22/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/23/2021
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ProCast Products

Material Information

The concrete mix design number: PRO18051
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: TT
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 4

DIME Test ID: 2021-04-22-37-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/10/2021
Date Tested: 04/22/2021
Submitted By Organization: Pro-Cast Products Inc.
Organization Address: 27417 E. Third St., PO Box 602,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: chad@procast.us
Organization Phone: (909) 793-7602
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 74 F

Test 2 of 4

DIME Test ID: 2021-04-22-37-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 06/10/2021
Date Tested: 04/22/2021
Submitted By Organization: Pro-Cast Products Inc.
Organization Address: 27417 E. Third St., PO Box 602,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: chad@procast.us
Organization Phone: (909) 793-7602
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 8 inch

Test 3 of 4

DIME Test ID: 2021-04-22-37-3
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/10/2021
Date Tested: 05/20/2021
Submitted By Organization: Pro-Cast Products Inc.
Organization Address: 27417 E. Third St., PO Box 602,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: chad@procast.us
Organization Phone: (909) 793-7602
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 8240 psi
Maximum load on cylinder 1 234490 lb
Maximum load on cylinder 2 231300 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 0
Correction factor for cylinder 2 0
Age of specimen 28 days
Age of specimen in hours 0 hours

Test 4 of 4

DIME Test ID: 2021-04-22-37-4
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 06/10/2021
Date Tested: 04/22/2021
Submitted By Organization: Pro-Cast Products Inc.
Organization Address: 27417 E. Third St., PO Box 602,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: chad@procast.us
Organization Phone: (909) 793-7602
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample PRO18051
Volume of the measure 0.25 ft^3
Density of concrete 149 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data