Project Information
Project ID: 215096 DEA: 11428104 EFIS: 1117000028
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R0.3/R23.0
Work Description: CULVERT REPAIRS, CONC. INVERT PAVING, MODIFY LANDSCAPE AND ELECTRICAL.
Location Description: SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM MORENA BOULEVARD UNDERCROSSING TO 1.1 MILES EAST OF LAKE JENNINGS PARK ROAD UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real , Suite 200, Carlsbad, CA 92008
Resident Engineer: Gustaf Silva Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2021-06-03-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 06/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2021
The quantity of what the sample constitutes: 28,804 lbs
A brief description of the sample: #4 Grade 60 Epoxy Coated Rebar
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coating
Material Information
Rebar Heat Number(s): 1202027475,
1201028159,
1202028994
Rebar Epoxy Batch Number(s):
Rebar Coating Specification: ASTM A775
Rebar Size (#): 4
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coating
Rebar Powder Manufacturer:
Release Number:
Quality Assurance Code:
Test Results
Test 1 of 2
DIME Test ID: 2021-06-03-5-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/10/2021
Date Tested: 06/09/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
1
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
0.2
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
Test 2 of 2
DIME Test ID: 2021-06-03-5-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/10/2021
Date Tested: 06/09/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
9.92
|
Second Bar Mean
|
9.61
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
12
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
9.76
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|