Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212252 DEA: 033F5604 EFIS: 0313000033
QA Service Level: 1
DIST-CO-RTE-PM: 03-SUT,YUB-20-17.0/17.1,0.0/0.4
Work Description: INSTALL CAST-IN-STEEL SHELL CONCRETE PILE.
Location Description: SUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD
Contractor Name: CALIFORNIA ENGINEERING CONTRACTORS, INC.
Contractor Address: 20 HAPPY VALLEY ROAD, PLEASANTON CA 94566
Resident Engineer: Selvendran Manoharan Structure Rep.: Brent Bullard
DIME Sample ID: 2021-06-03-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Per Request
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 06/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/03/2021
The quantity of what the sample constitutes: 1
A brief description of the sample: Sq Rebar
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown
Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Rebar Heat Number(s): unknown
Hoop Manufacturer Lot Number(s): NA
Material Standard Code: ASTM A706
Material Grade: 40
Rebar Size: #9
Diameter of Hoop: 2'-0"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Unknown
Welding Company: unknown
Coating Standards: Uncoated
Weld Type: Flash Welded
DIME Test ID: 2021-06-03-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 06/03/2021
Date Tested: 06/03/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 1 | 1 | 9/29mm | 1 | 85947.37 | 85947 | OK Necking | fsaylor |
| |
UTM
|
400kip
|
Temperature
|
72 f
|