Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-06-01-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 06/01/2021
Date that the sample was received by the laboratory/organization performing the testing: 06/01/2021
The quantity of what the sample constitutes: 1 box
A brief description of the sample: CCRL pozzolan
From where was the sample collected: Source
Laboratory sample identification: CM218069
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL
DIME Test ID: 2021-06-01-2-1
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/21/2022
Date Tested: 06/22/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
yes
|
Age of specimen
|
15 days
|
The amount of flow
|
120.00 %
|
The amount of water used
|
46.4 %
|
Compressive strength of 1st specimen
|
5042 psi
|
Compressive strength of 2nd specimen
|
5890 psi
|
Compressive strength of 3rd specimen
|
no data
|
Average Compressive strength (to nearest 10 psi)
|
0 psi
|
Average Compressive strength (to nearest 10 psi) control group
|
0 psi
|
Strength Activity Index of Portland Cement per ASTM C109
|
no data
|
DIME Test ID: 2021-06-01-2-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/21/2022
Date Tested: 06/01/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
yes
|
Age of specimen
|
0 days
|
The amount of flow
|
120.00 %
|
The amount of water used
|
46.4 %
|
Compressive strength of 1st specimen
|
no data
|
Compressive strength of 2nd specimen
|
no data
|
Compressive strength of 3rd specimen
|
4544 psi
|
Average Compressive strength (to nearest 10 psi)
|
no data
|
Average Compressive strength (to nearest 10 psi) control group
|
0 psi
|
Strength Activity Index of Portland Cement per ASTM C109
|
no data
|
DIME Test ID: 2021-06-01-2-3
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Verified Date: 03/21/2022
Date Tested: 06/17/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specimen A Initial measurement at 24 hours
|
0.2627 in
|
Specimen B Initial measurement at 24 hours
|
0.2828 in
|
Specimen C Initial measurement at 24 hours
|
0.2693 in
|
Specimen D Initial measurement at 24 hours
|
0.0097 in
|
Specimen A Final measurement at 14 days
|
0.2527 in
|
Specimen B Final measurement at 14 days
|
0.2731 in
|
Specimen C Final measurement at 14 days
|
0.2599 in
|
Specimen D Final measurement at 14 days
|
0 in
|
The average length of change of the four specimens
|
-0.097 %
|