Project ID: 214945 DEA: 051G1304 EFIS: 0514000110
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-1-M29.9/49.2
Work Description: COLD PLANE AC PAVEMENT, PLACE RHMA-G & HMA (TYPE A).
Location Description: SANTA BARBARA COUNTY NEAR SANTA MARIA FROM CALIFORNIA BOULEVARD TO ROUTE 166
Contractor Name: CAL PORTLAND CONSTRUCTION
Contractor Address: 1625 E Donovan Road, Santa Maria, CA 93454
Resident Engineer: Thomas Peterson Structure Rep.: Unknown
DIME Sample ID: 2021-05-21-15
TL Number from the TL Form: 210521D
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 05/21/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/25/2021
The quantity of what the sample constitutes: 1 can
A brief description of the sample: binder
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: World Oil
Performance Grade: PG 64-10
Modified: No
Lot number: 1
Sublot number: 1
Tank number:
Time of sample:
HMA Supplier: Calportland
Certified Asphalt Supplier: Lunday Thagard Company-World Oil - South Gate CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-05-21-15-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 06/07/2021
Date Tested: 05/27/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: as per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
161.253 grams
|
Mass of empty container #2
|
171.431 grams
|
Mass of container #1 before test (m1i)
|
196.580 grams
|
Mass of container #2 before test (m2i)
|
206.990 grams
|
Mass of container #1 after test (m1f)
|
196.573 grams
|
Mass of container #2 after test (m2f)
|
206.975 grams
|
Average mass change
|
-0.031 percent
|
DIME Test ID: 2021-05-21-15-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/07/2021
Date Tested: 05/27/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: ORIGas per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.163 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
87.5 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.357 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.36 kPa
|
DIME Test ID: 2021-05-21-15-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/07/2021
Date Tested: 05/27/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: RTFOas per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.357 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
84.4 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
3.575 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
3.59 kPa
|
DIME Test ID: 2021-05-21-15-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/07/2021
Date Tested: 06/04/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Test Gap
|
2 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
1.00 %
|
Stress Amplitude
|
40.423 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
47.3 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
4041.119 kPa
|
Test Temperature (Specimen 1)
|
31.0 C
|
(G*) x sin(δ)=
|
2970 kPa
|
DIME Test ID: 2021-05-21-15-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 06/07/2021
Date Tested: 06/04/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s
|
-0.1 C
|
Maximum test bath temperature at 240 s
|
0.0 C
|
Time of test load application
|
no data HH:MM:SS
|
File name of test data
|
no data
|
Time beam in bath
|
no data
|
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
981.0 mN
|
Beam deflection 60.0 s
|
1.894 µm
|
Measured Stiffness Modulus 60.0 s
|
41.800 mPa
|
Estimated Stiffness Modulus 60.0 s
|
41.800 mPa
|
Difference between stiffness moduli 60.0 s
|
-1.83 %
|
Estimated m-value 60.0 s
|
0.392
|