Print Report | Back to Sample Detail

Sample Record for 2021-05-03-22

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212056 DEA: 033H7204 EFIS: 0318000054 QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-80-R9.2/R9.6
Work Description: remove mudslide -Construct TWLTL/turn pockets, widen shoulders, provide improved access for bicyclists/pedestrians, establish a clear recovery zone of 20 feet, and rehabilitate Class II pavement
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-03-22
TL Number from the TL Form:
Sample Submitted By Organization: Jensen Precast - Fontana
Sample Organization Contact: (909) 350-4111
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/05/2021
The quantity of what the sample constitutes: 4 cylinders
A brief description of the sample: 6"x12" Concrete Samples
From where was the sample collected: Manufacturer
Laboratory sample identification: CB1813010007
Structure unique identifier: 03-20000087 04 Butte
Structure name: Hwy 70 Cox Lane
The fabricator/manufacturer/facility name: Jensen Precast

Material Information

The concrete mix design number: 10
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 44069
Concrete batch plant: Jensen Precast
The fabricator/manufacturer designation for the sample: Batch plant
A detailed description of where the material sample was collected: conveyor belt
Where the material sample would have been placed if not sampled: Form
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2021-05-03-22-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/17/2021
Date Tested: 05/03/2021
Submitted By Organization: Jensen Precast - Fontana
Organization Address: 14221 San Bernardino Ave.,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92335
Organization Email: rcuevas@jensenprecast.com
Organization Phone: (909) 350-4111
General Comments for this Test: Two more samples available for a latter test. Test performed by Terracon, 1355 E Cooley Dr. Ste. C Colton CA. 92324
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C39 - Ground End
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5640 psi
Maximum load on cylinder 1 157920 lb
Maximum load on cylinder 2 161110 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours 168 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.