Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212912 DEA: 010H6904 EFIS: 0118000074
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-15.1/15.5, 15.1 - 15.5
Work Description: Roadway stabilization & retaining wall repair
Location Description:
Contractor Name: Golden State Bridge, INC
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Karen Sanders Structure Rep.: Joshua Lee
DIME Sample ID: 2021-05-03-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 05/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/05/2021
The quantity of what the sample constitutes: 7
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Insteel
DIME Test ID: 2021-05-03-6-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/05/2021
Date Tested: 05/05/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 620715 | 120137164147 | 0.218 | 61086 | 55126.3 | 29 | 1.99 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2021-05-03-6-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/05/2021
Date Tested: 05/05/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 620715 | 120137164148 | 0.218 | 61159 | 57361.6 | 36 | 1.9 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|