Print Report | Back to Sample Detail

Sample Record for 2021-04-06-49

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-06-49
TL Number from the TL Form:
Sample Submitted By Organization: RJ Noble Company
Sample Organization Contact: (714) 235-7028
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 04/06/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2021
The quantity of what the sample constitutes: 4 CANS 64-28M
A brief description of the sample: 4 CANS OF 64-28M
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Refining-marathon bakersfield

Material Information

Performance Grade: PG 64-28 M
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Marathon Petroleum Co. LP - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2021-04-06-49-1
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/28/2021
Date Tested: 04/06/2021
Submitted By Organization: RJ Noble Company
Organization Address: 15505 East Lincoln Avenue, P.O. BOX 620
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: qualitycontrol@rjnoblecompany.com
Organization Phone: (714) 235-7028
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified: I GOT THE PHASE ANGLE # FROM THE R.T.FO RESIDUE. I THINK THERE IS AN ISSUE WITH THE RED ASTRIX AS TO WHAT YOU GUYS WANT VS WHAT TIS FORM IS WANTING.
Phase Original binder
Test Plate Diameter 25 mm
Phase Angle (δ) (for the 10 cycles) 62.6 degree
Dynamic Shear, G*/sin(δ) 64.00 kPa